Trasducer voltage: 5 V (max 6 load cells 350 Ohm)
Measuring range: -0.5 ? +3.5 mV/V (optional -3.9 ? +3.9 mV/V)
Offset, drift: 0.02 microV/°C
Linearity: <0.01% of full scale
Gain drift: <0.001% full scale/ °C
LED status: 4 red
D/A convertitor: 24 bit
Displayable resolution: 60.000 divisions displayable on net weight
Set decimal: 0.0 ; 0.00 ; 0.000
Filter: adjustable 0.1 ? 25 Hz
Tool voltage: 24 V c.c. ±15% - power 5 W
Temperature range: -10/+40 °C
Storage Temperature: -20/+50°C
Logic output: 2 relays (clean contact) MAX 24 V c.c./100 mA cad.
Logic input: 2 optoisolated 24 V c.c. PNP (External voltage)
Serial door: USB, RS232C o RS422/RS485 with ASCII or Modbus RTU protocols
Trasmission distance: 15m (RS232C), 1000m (RS422 e RS485)
Others fieldbus comunication: CANopen, Modbus-Plus and other
Peak Hold function: for dynamic measures
Baud rate: 2400, 9600, 19200, 38400, 115200 adjustable
Regulatory compliance: EN61326-1, EN55011 and EN55014 for EMC; EN61010-1 for electrical security
ATEX II 3 GD EEx nR IIC IP65 T6: EN 13463-1: 2003; EN 60529: 1991 + A1: 2000 IEC 60079-0:
2004; IEC 60079-15: 2005
Analogic output (optional):
Optoisolated 16 bit, Tension:0?5 or 0?10V (R >10 K Ohm),
Current: 0?20 o 4?20mA (R < 300 Ohm), Linearity: 0,03 of full scale
BCD optional output: via external modules
FIELDBUS optional protocol: PROFIBUS, DEVICENET
AC power supply: 115 / 230 Vdc 50/60 Hz